4.2.3.9. FLAG
SCREEN
1.- Observations
When the Flag SCREEN is TRUE the following messages are written in the screen:
.- At the beginning of the simulation:
number of steps= |
# of temporal steps of a simulation |
number of repeated simulations= |
Actual repetition / # of repetitions |
.- At the beginning of the simulation (if confinements are activated):
ENERGY CONF I= |
1st confinement energy in the I direction |
.- During the simulation:
VOLT FACE 1= |
Scalar potential in FACE 1 (V) |
VOLT FACE 4= |
Scalar potential in FACE 2 (V) |
# OF ITERATION= |
Present number of the iteration of the simulation |
Time= |
Time of the simulation (s) |
ND4= |
# particles in the simulation box entering through surface 4 |
ND1= |
# particles in the simulation box entering through surface 1 |
NE4L4= |
# particles entering surface 4 and leaving surface 4 |
NE1L4= |
# particles entering surface 1 and leaving surface 4 |
NE4L1= |
# particles entering surface 4 and leaving surface 1 |
NE1L1= |
# particles entering surface 1 and leaving surface 1 |
RAMO CURRENT (1/L)= |
Ramo value of the curren according to the simple expression CURRENT1DRAMO=TRUE |
ENECIN= |
Kinetic energy of the IDBG particle |
.- When an electrons have overcome the energy maximum:
This is the event number= |
Number of event where particles overcome the energy maximum |
Particle = |
Number of particle |
Cell = |
x index, y index, z index |
Energy= |
kinetic energy |
Momentum = |
x momentum, y momentum, z momentum |
Material= |
Number of material |
Volum= |
Name of the volum |